Subject: Re: Reproducible test case, and some answers!!!
From: Linus Nielsen Feltzing (linus_at_haxx.se)
Date: 2003-02-06


Mike Holden wrote:
> After examining the code, I traced the problem to power_init() in
> powermgmt.c, in the call to charger_enable(true), which is called in the
> last but one section, just before calling create_thread(). If I comment
> out the if() and subsequent call to charger_enable(true), then archos
> boots fine and functions correctly, no matter what the setting of BLD.
>
> The charger does not kick in immediately in this case, but it does start
> from the normal runtime checking within a minute or so.

I'd say that his clearly shows that the port pin used for controlling
the charger on the older models is used for something else on the FM
recorder.

We need schematics.

/Linus