Rockbox mail archive
Subject: Re: H300 - Bootloader USB mode?
Re: H300 - Bootloader USB mode?
Hi Linus,
I've performed some checks by using a USB monitor program -
http://www.hhdsoftware.com/usbmon.html which allows trial runs for free.
Unfortunately this shows nothing happening at all from the PC end when using
the bootloader USB mode.
As a comparison, if I boot Rockbox first, the logged data starts with the
following:
000001: Get Status Request (DOWN), 07.04.2006 12:59:41.2451792 +142.9856032
Get status from Device. Data length 0x2 bytes (00 00)
000002: Control Transfer (UP), 07.04.2006 12:59:41.2451792 +0.0
Pipe Handle: 0x85a0a9f4
03 00 ..
Setup Packet
80 00 00 00 00 00 02 00€.......
Recipient: Device
Request Type: Standard
Direction: Device->Host
Request: 0x0 (GET_STATUS)
Value: 0x0
Index: 0x0
Length: 0x2
...
(This then succeeds every time.)
I've now tried this on 2 other PCs - both running Windows XP SP2 - and all 3
machines give exactly the same results. In the unlikely case it's relevant,
my Iriver firmware is 1.28E, and (duh) I am using the USB 2.0 Device port
(not the USB 1.1 Host).
Any other ideas for ways in which us users could help..?
Steve Bavin
Received on Fri Apr 7 14:37:45 2006
Page was last modified "Jan 10 2012" The Rockbox Crew
|