Subject: Re: Button Polling

Re: Button Polling

From: Alex Wenger <a.wenger_at_gmx.de>
Date: Thu, 31 Oct 2002 09:00:04 +0100

Hi,

> I would be very surprised if this was a problem with the
> polling frequency. It may be remedied by adjusting the
> voltage threshold for the Right key...
>
> We can run a test on your machine to see if we can fix
> this. Join the IRC channel.

i have this problem too.

AN5 - 000-001
AN5 Down - 3FF
AN5 Right - 189-193
AN5 Left - 25F-263
AN4 Play - 330-334

Could it be that when i press the key very short,
the sampling looks like that: ?
 
       I /\ I
       I/ \I
       / \
      / \
-----/ \--------

the "I"s are the sampling Points.

and the value is then in the Range 330-334 aka "Play"?