Rockbox mail archiveSubject: Re: Serial remote code "STOP" (0xC2) partially not workingRe: Serial remote code "STOP" (0xC2) partially not working
From: Steve Russell <pic.projects_at_ntlworld.com>
Date: Sun, 21 Mar 2004 15:13:19 -0000 "Matthias Klumpp" <Matthias.Klumpp_at_gmx.de> wrote in message > Sending 0xC2 results in the following (measured directly at the AJB input): > > start level is high (3.3V), then it goes: > 200us low > 110us high > 410us low > then high for ever > > Assuming a time grid of 100us, that would end up in: > 0 0100 0011 > putting it the other way round (it was LSB first) > 1100 0010 0 > that is 0xC2 with Stop Bit =0 (why that ?) That looks good - the a bit at 9600bps lasts for about 104us .... the 0 is the Start bit, not the Stop bit. >From your other post, it does seem that this may be a problem with the Rockbox Player software. Steve. _______________________________________________ http://cool.haxx.se/mailman/listinfo/rockbox Received on 2004-03-21 Page template was last modified "Tue Sep 7 00:00:02 2021" The Rockbox Crew -- Privacy Policy |