Rockbox mail archiveSubject: Re: jethead71: firmware/target/coldfire system-coldfire.c,1.2,1.3Re: jethead71: firmware/target/coldfire system-coldfire.c,1.2,1.3
From: Michael Sevakis <jethead71_at_sbcglobal.net>
Date: Fri, 3 Nov 2006 09:15:10 -0500 I had a feeling it might be that but don't like to jump to conclusions w/o invesitgating. So the only one with a nice reset/reboot is the H120? It raised a question though: how long does the reset take? It's supposed to have about 1ms to put it high again before it goes to standby. If the pin could be high again within a short enough time it might work. ----- Original Message ----- From: "Linus Nielsen Feltzing" <linus_at_haxx.se> To: <rockbox-dev_at_cool.haxx.se> Sent: Friday, November 03, 2006 5:24 AM Subject: Re: jethead71: firmware/target/coldfire system-coldfire.c,1.2,1.3 > cvs_at_labb.contactor.se wrote: > > More tweak to ColdFire default exception handler. iRiver reboots on > > power press but x5 just shuts down. Haven't yet thought much about > > why or how to make it reboot on x5 if it's possible. > > The X5 shuts down because the KEEP_ACT signal goes inactive when the > port pins are tri-stated at reset. It's the same with H300. > > Linus > Received on 2006-11-03 Page template was last modified "Tue Sep 7 00:00:02 2021" The Rockbox Crew -- Privacy Policy |