Rockbox mail archiveSubject: Re: Sansa View - weekly updateRe: Sansa View - weekly update
From: Rafaël Carré <rafael.carre_at_gmail.com>
Date: Sun, 21 Jun 2009 11:04:52 +0200 -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 On Sat, 20 Jun 2009 21:13:16 -0500 Robert Keevil <rkeevil_at_gmail.com> wrote: > Since it looks so similar to the e200 (at > least to me) is it safe to assume that the View is likely to contain > another Renesas LCD controller? I am not sure of this: now that you have found the lowest level LCD functions you must find the command set of the View controller. > What is the best way to try and > pin-point which model is in use? (The HD66789 in the e200 is limited > to 176x220 - the HD66776 and HD66781 are possibilities for 240x320, > but they produced several other controllers after those). > Since Rockbox code runs after the OF bootloader, how much hardware > initialisation is required to get the LCD up and running? On the e200 > RB inits the GPIOs and LCD controller again. > I would appreciate any tips, advice or insight! Just download the datasheet of a candidate controller, and see if all the commands you found have a correct meaning. Since the lcd_init_device has a lot of commands I think the quick way to match one controller is to look at lcd_write_reg or LCD_FB_BASE_REG (device framebuffer). - -- Rafaël Carré -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.4.9 (GNU/Linux) iEYEARECAAYFAko997QACgkQYWCeGMCv8Q+XNQCgzYrLV8exdwvxaYQ9HJYy2bb5 qYAAn24LJFd7hT2mvewGXmMS7V74dlmQ =ECEy -----END PGP SIGNATURE----- Received on 2009-06-21 Page template was last modified "Tue Sep 7 00:00:02 2021" The Rockbox Crew -- Privacy Policy |